AUX Mini Split Review

AUX Mini Split Review: Pricing, Specs & Features

AUX is a Chinese air conditioning brand established in 1994 under its parent company, AUX Group. While the group has other businesses such as real estate development, healthcare and investment services, its brand, AUX is primarily used for various air conditioning products including mini splits.

As of 2023, AUX Group has 6 research and development centers which 5 of which are located in China and one in Japan. AUX Group also has 11 manufacturing plants located across China and other countries such as Poland, Brazil and Thailand.

In 2023, a reputable Chinese ranking website ranked AUX as the top 4 air conditioner brand in China. The preceding brands are well-known brands; Gree, Midea and Haier.

According to Frost & Sullivan, the world’s leading corporate growth consulting company, AUX Air Conditioning ranks among the top 3 in the world in terms of cumulative sales of air conditioners for 4 years consecutive, from 2018 to 2021.

Overview

AUX mini splits are sold/distributed by AUXUSA in the United States.

AUXUSA is based in California to service the North American market. At present time, there are more than 30 direct sales outlets online, as well as cooperative agents in Texas, Oregon, Nevada, Tennessee and other states that are affiliated with the company.

As of writing, AUX offers 3 variants of mini splits; 12000 BTU, 24000 BTU and 36000 BTU.

All AUX mini splits are AHRI certified which means their quality is on par with other AHRI-certified mini splits. In addition, AUX mini splits are also ETL certified which means they are electrically safe to use.

Pricing

Official from AUXUSA:

1-Ton, 12000 BTU

  • AUX 12,000 BTU with 12 ft line set, no WiFi control: $820
  • AUX 12,000 BTU with 12 ft line set and WiFi control: $850
  • AUX 12,000 BTU with 25 ft line set, no WiFi control: $920
  • AUX 12,000 BTU with 25 ft line set and WiFi control: $950

2-Ton, 24000 BTU

  • AUX 24,000 BTU with 12 ft line set, no WiFi control: $1,200
  • AUX 24,000 BTU with 12 ft line set and WiFi control: $1,320
  • AUX 24,000 BTU with 25 ft line set, no WiFi control: $1,400
  • AUX 24,000 BTU with 25 ft line set and WiFi control: $1,580

3-Ton, 36000 BTU

  • AUX 36,000 BTU with 12 ft line set, no WiFi control: $2,100
  • AUX 36,000 BTU with 12 ft line set and WiFi control: $2,200
  • AUX 36,000 BTU with 25 ft line set, no WiFi control: $2,300
  • AUX 36,000 BTU with 25 ft line set and WiFi control: $2,400

Compressor, Efficiency and Operating Range

AUX mini splits use Hitachi Highly and Toshiba GMCC compressors which are reliable and widely available. These compressors are also found in other mini splits.

The J-Smart AUX mini splits have an efficiency of SEER 17 for cooling and HSPF 9 for heating which is on par with many entry-level mini splits including Daikin 17, Fujitsu Infinite Comfort and Mitsubishi MSZ-JP.

AUX mini splits can comfortably produce warm air down to an ambient air temperature of 19.4°F. The AUX indoor unit noise level is controlled under 30 dB which is on par with many of its rivals.

Indoor Unit, Remote Controller and Features

The front panel of the indoor unit of AUX mini splits has LEDs that conveniently display the temperature. The unit’s air outlet has horizontal and vertical grilles for airflow direction control.

AUX mini splits come with a backlit remote controller. The backlight automatically turns off after some time which is good for sleep. Using the remote controller, you change the operation mode of AUX mini splits between Auto, Cool, Heat, Dry and Fan.

The remote controller also can be used to turn on the iClean function which cleans the evaporator coil. AUX mini splits also come with an ECO mode that saves energy. In addition, the Health function can be turned on to activate negative ions.

Refrigerant and Environmental Impact

AUX mini splits use R410A refrigerant, a non-flammable refrigerant that does not contribute to ozone depletion.

Installation Kit

AUX mini splits come with a 12 ft or 25 ft line set, an 8 ft electrical wire for the outdoor unit, a drain pipe for the indoor unit, plastic pipe wrap, wall bracket for the indoor unit and neoprene putty to seal holes.

Warranty

AUX mini splits have 5 years warranty on compressor and 1 year warranty on parts. Labor warranty subject to individual installer or contractor.

Final Verdict

I think AUX mini splits are acceptable given their price. I consider them entry-level mini splits which means that you should not expect high efficiency and great heating performance. At 19.4°F, the heating performance is not good enough for cold climates but acceptable if your place hardly falls below freezing. The WiFi connection seems easy to navigate and AUX also provides good user manuals. Overall, I think AUX mini splits are a bargain and they provide great value if you’re looking for something basic and functional.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

2 Comments

  1. Hello.
    I purchased an AUX mini split unit for my sunroom and it was installed April 2024.
    There is no safety locking cap for the refrigerant access port.
    I contacted the company via the BBB California and they company did admit the safety cap was not included with the unit but should have been included. The company has not included a safety cap for my make and model.
    I understand this to be a safety matter, by the inspector who reviewed the construction of the sunroom, to include the mini split.
    Is it possible to have the refrigerant access port safety cap for model number ASWH12U3, serial number JIR1D1US-A delivered to me from you?

    Thank you for your time and consideration of this request.

    1. Hi,

      Sorry I don’t sell AUX mini splits and other refrigeration parts. I’m an independent third party HVAC reviewers and information provider.

      The refrigerant access port is used to release the refrigerant stored inside the compressor during initial start up. You may purchase a basic brass material cap on Amazon or any other hardware stores to cap the port. Using a safety locking cap will prevent others from tampering the port as you need a special tool to open up one of these safety locking caps. Safety locking caps can also be purchase from Amazon or any other hardware stores.

      Thank you.