Psychrometric Analysis Course

Learn practical psychrometric analysis for AHU cooling coil sizing, air conditioning process analysis, AHU selection review, and troubleshooting.

70+ Enrolled
1–2 Hrs
English
Intermediate Level
18 Lessons
English Subtitle
Self-Paced
Certification
One-time purchase: $79.99

Also included in Basic Membership from $20/month or $220/year.

Psychrometric Analysis Podia Product Image

Psychrometrics Is Difficult When You Only Learn the Chart

You know how a psychrometric chart looks, but still struggle to connect the chart with cooling coil sizing, mixed air, fan heat gain, duct heat gain, AHU selection, and real air conditioning problems.

1

You Can Read Points, But Not the Full Process

You know dry bulb, wet bulb, humidity ratio, and enthalpy, but still feel unsure how to connect them into a complete air conditioning process.

2

Cooling Coil Sizing Feels Unclear

You know the cooling load, but still struggle to determine off-coil temperature, on-coil temperature, coil capacity, sensible heat ratio, and mixed air condition.

3

AHU Selection Reports Are Hard to Interpret

You receive an AHU selection report, but still feel unsure how to compare the selected coil, fan, airflow, static pressure, and actual performance against your design.

4

Troubleshooting Without Psychrometrics Becomes Guesswork

When a system has cooling, humidity, or airflow issues, you know something is wrong but not know how to use air properties to identify the likely cause.

Who This Is For

Student

HVAC Design Learners

For learners who want to understand psychrometrics beyond basic chart reading.

Engineer

Junior HVAC Engineers

For engineers who need to size AHU cooling coils, understand air-side processes, and review AHU selection data.

Company

Facility and Maintenance Teams

For people who troubleshoot comfort, humidity, cooling, airflow, and AHU performance problems.

Project

Project Engineers and Site Engineers

For project personnel who need to understand AHU selection, supply air condition, duct heat gain, fan heat gain, and cooling performance issues.

Technician

HVAC Contractors and Technicians

For contractors who want to understand how cooling coil sizing, air temperature, humidity, and airflow affect system performance.

This Course May Not Be for You If…

  • You are completely new to HVAC and do not understand basic air conditioning systems yet.
  • You only want a simple psychrometric chart explanation without calculation or application.
  • You are looking for advanced research-level psychrometrics.
  • You want someone to troubleshoot your actual project instead of learning the analysis method.

New to HVAC? Start with the HVAC Beginner Course first.
Need project-specific review? View HVAC Engineering Services.

What You Will Learn in This Course

01

Psychrometric Chart Reading

Learn how to read the psychrometric chart and understand the key air properties used in HVAC analysis.

02

Cooling Coil Sizing

Learn how to determine on-coil and off-coil conditions and calculate AHU cooling coil capacity.

03

Sensible Heat Ratio and Design Conditions

Understand sensible heat ratio, indoor design conditions, and how they affect cooling coil sizing.

04

Fan and Duct Heat Gain

Learn how fan motor heat gain, supply duct heat gain, and return path heat gain affect air conditions and coil load.

05

AHU Selection Review

Learn how to interpret an AHU selection report and compare actual selection results against design expectations.

06

Troubleshooting Using Psychrometrics

Learn how psychrometric analysis can help you understand cooling problems, high outdoor airflow, and other air conditioning performance issues.

Course Outline

This course is structured around practical psychrometric analysis for AHU cooling coil sizing, AHU selection review, and troubleshooting. You will start with chart and calculator setup, then move into cooling coil sizing, design versus selection, and advanced application.

To start, you’ll learn what is the coil load calculator and understand how to read the psychrometric chart. Then, you’ll be given to download an excel calculator that will support your progress in this course and future applications.

Lessons:

  • Calculator & Chart Explanation
  • Coil Load Calculator

Part 1 is where you’ll learn how to determine the on/off coil temperature of a cooling coil in order to calculate the coil capacity based on a given cooling load requirement. You’ll also learn how to calculate the heat gain from fan motor and supply/return duct.

Lessons:

  • 1.1 Sensible Heat Ratio
  • 1.2 Indoor Design Conditions
  • 1.3 Off Coil Temperature
  • 1.4 Fan Motor Heat Gain
  • 1.5 Supply Duct Heat Gain
  • 1.6 Return Path Heat Gain
  • 1.7 Mixed Air Temperature
  • 1.8 On Coil Temperature

In Part 2, you’ll be presented an AHU selection report and the important parameters within the AHU will be explained. Then, you’ll learn how the actual selection differ from the design, how to interpret it and what to do about it.

Lessons:

  • 2.1 AHU Selection Report
  • 2.2 Supply Fan Selection
  • 2.3 Static Pressure & Duct Losses

Part 3 is about application. You’ll go through an air conditioning problem with several scenarios to demonstrate how to use psychrometric analysis in troubleshooting. You’ll also learn what factors will affect cooling coil sizing.

Lessons:

  • 3.1 Cooling Problems
  • 3.2 High Outdoor Airflow

The final section of this course includes a thank you message and takeaways from the instructor, and a course assessment quiz to test your knowledge.

Lessons:

  • Course Completion
  • Course Assessment Quiz
  • Certificate of Completion

What You Get Inside This Course

18 Self-Paced Lessons

Learn online at your own pace. You can complete one module per day or move faster depending on your schedule.

3 Structured Modules

The course is arranged in a practical sequence from understanding the psychrometric to getting the right design conditions for coil sizing.

Coil Load Excel Calculator

Use the included Excel calculator to plot air conditioning processes, calculate coil load, and compare design vs selection.

Practical Working Example

Follow a working example with drawings, load requirement, and duct layout.

Certificate of Completion

Learners receive a certificate upon course completion.

Access to Course Platform

Lessons are delivered online through my course platform.

By the End of This Course, You Should Be Able To…

  • Read the psychrometric chart with more confidence.
  • Understand sensible heat ratio in cooling coil sizing.
  • Determine indoor design conditions for analysis.
  • Estimate off-coil and on-coil air conditions.
  • Calculate fan motor heat gain.
  • Account for supply/return duct heat gain.
  • Determine mixed air temperature.
  • Review AHU selection report values.
  • Understand the difference between design and actual AHU selection.
  • Connect supply fan selection with AHU performance.
  • Understand how static pressure and duct losses affect selection.
  • Apply psychrometric thinking to cooling problems.
  • Understand the impact of high outdoor airflow.

Preview the Learning Journey

This course teaches psychrometric analysis through step-by-step explanation, calculator demonstration, chart plotting, and actual AHU review. You will see how air properties connect to real cooling coil sizing and troubleshooting decisions.

Choose How You Want to Learn

Buy This Course

$79.99

one-time purchase

Best if you only want to learn psychrometric analysis, cooling coil sizing, and AHU air-side analysis.

Included:

  • Psychrometric Analysis Course
  • 18 lessons
  • 3 modules
  • Coil load excel calculator
  • Certificate of completion
  • Self-paced access

Join Pro Membership

$20

per month

or

$220

per year

Best for learners who want this course plus selected beginner resources beyond this course.

Included:

  • Psychrometric Analysis Course
  • RTS Cooling Load Calculation Course
  • Chilled Water System Design Course
  • Duct Design
  • HVAC Beginner Course
  • Pro resources and references
  • Exclusive Pro Zone community

Should You Buy the Course or Join the Membership?

Buy Psychrometric Analysis Course

You only want this course and prefer a one-time purchase.

Join Pro Membership

You want multiple HVAC design courses, technical resources, community access, and continuous learning.

Start with HVAC Beginner Course

You are new to HVAC and need stronger fundamentals first.

Recommendation: If you only want to learn psychrometric analysis, buy this course. If you want to build a broader HVAC design foundation, Pro Membership is the better learning path because psychrometrics connects closely with cooling load calculation, duct design, chilled water system design, AHU selection, and troubleshooting.

How Psychrometric Analysis Fits Into HVAC Design

Psychrometrics connects air temperature, humidity, cooling load, coil capacity, outdoor air, fan heat, duct heat gain, and AHU selection.

Without psychrometric analysis, it is difficult to properly understand:

  • Why a cooling coil is sized a certain way?
  • How supply air condition is determined?
  • How outdoor air affects coil load?
  • How fan heat affects supply air?
  • Why AHU selection differs from design calculation?
  • Why some rooms feel cold but humid?
  • Why an air conditioning system may struggle under certain conditions?

This course helps you understand the air-side behavior behind HVAC design and troubleshooting.

Learn from Practical HVAC Field Experience

This course is taught by Yu Chang Zhen, founder of aircondlounge. The teaching approach is based on practical HVAC experience across design, installation, operation, maintenance, commissioning, troubleshooting, and technical content development.

MBOT Professional Technologist

MASHRAE Independent CxS

HRD Corp TTT Certified Trainer

10+ Years HVAC Field Experience

“My goal is to help learners understand HVAC in a practical, structured, and field-relevant way, not just memorize theory.”

Hero Section Real photo of me explaining at site 2

FAQ

This course is better for learners who already understand basic HVAC and air conditioning concepts. If you are completely new to HVAC, start with the HVAC Beginner Course first.

This is a self-paced online course. You can access the lessons online and learn at your own pace.

The course covers psychrometric chart explanation, coil load calculator, cooling coil sizing, sensible heat ratio, indoor design conditions, off-coil and on-coil temperature, fan motor heat gain, duct heat gain, mixed air temperature, AHU selection report review, supply fan selection, static pressure and duct losses, cooling problems, and high outdoor airflow.

Yes. Cooling coil sizing is one of the main parts of the course. The course covers on/off coil temperature, coil capacity, fan heat gain, duct heat gain, mixed air, and related calculations.

Yes. The course includes a custom Excel coil load calculator used to plot processes and calculate coil load. 

Yes. A certificate of completion is provided after finishing the course.

Yes. This course is included in Pro Membership.

Buy this course if you only want psychrometric analysis. Join Pro Membership if you want access to multiple HVAC design courses and continuous learning resources.

Continue Your HVAC Learning Path

After completing this course, you can choose one of the following paths based on your needs to pursue further learning.

RTS Cooling Load Calculation Course

Learn how cooling load is calculated and how load affects equipment sizing and airflow requirement.

Chilled Water System Design Course

Learn how chilled water systems, chillers, pumps, cooling towers, flow rate, and system configuration connect to commercial HVAC design.

Start Learning Practical Psychrometric Analysis

If you want to understand psychrometric chart reading, AHU cooling coil sizing, fan heat gain, duct heat gain, mixed air, AHU selection review, and troubleshooting using air-side analysis, this course gives you a structured path to learn the workflow step by step.

Compare Membership Plans