Design and Consultation Service

I’m can help you design your HVAC systems and provide my advice to your HVAC problems.

10+

HVAC Systems

I know about various HVAC systems including mini split, multi split, VRF, chiller, energy recovery, exhaust fan and more.

7+

YEARS EXPERIENCE

I have more than 7 years of field experience in HVAC from design and installation to operation, maintenance and more.

LOAD CALCULATION

DUCT & PIPE SIZING

GRILLE & DIFFUSER SELECTION

EQUIPMENT SELECTION

EXHAUST & FRESH AIR DESIGN

AUTOCAD 2D & 3D

I Produce Professional and Presentable Work.

My design drawings and calculation reports are done professionally so that you and your associated parties can clearly understand my work.

DESIGN GUIDELINE

I Work Based on Your Project’s Requirements.

My work is based on internationally recognized standards and good engineering practices. If your project has specific design standards to follow, I’ll work based on that too.

WHAT I CAN DO FOR YOU

List of Services

My flexibility allows me to focus on helping people that are involved in niche markets, unique systems, innovative buildings and small scale projects.

Email Consultation

Ask my advice on brand selection, component sizing, installation location and troubleshooting.

Design & Layout Drawing

Load calculation, duct/pipe sizing, layout design, equipment selection, grille/diffuser selection, etc.

30 Minutes Zoom Discussion

Face-to-face discussion for matters such as general knowledge, industry insights and design practices.

Professional Service

Engage me as a freelance consultant, attend meeting, conduct presentation, provide training and others.

SAMPLE WORK

Email Consultation

Many homeowners ask me to verify their own HVAC design drawings, their contractor’s design, and some of them ask me to help them design the system they wish to have.

Brand Selection | Design Verification

Mini Split Sizing and Placement

Jill was designing his own mini split system for the bedrooms. However, he was not sure about the correct size and where is the best place to put the unit. After I provided my advice, he went on to ask for my opinion if the mini split model he choose was good. I give him my analysis and he got all the information he needs.

Design Check | Cost Reduction

Ductwork Design Check

Babak had designed a central air system with ducts, diffusers and grilles in place. He consulted me to check and verify his work. I gave him my advice and reduced some duct sizes to save him cost. We ended the design check and proceeded with a few more technical discussions afterward.

SAMPLE WORK

30 Minutes Zoom Meeting

Some people would like to have a quick conversation about specific HVAC topics. With face-to-face meeting, they’re able to understand better and ask questions on the spot.

General Discussion | Energy Savings

Green Technology and Energy Saving HVAC System

A climate activist met me to understand about the working principle of various HVAC systems, particularly those that have great potential to save energy and cause less harm to the environment. She wanted to present to the relevant authorities as part of the policy making process.

SAMPLE WORK

Design & Layout Drawing

Some projects are involved in niche markets where unique HVAC systems are needed. So, I can help clients, architects and even contractors to produce HVAC design drawings based on their needs.

HVAC Drawings | AutoCAD 3D

VRF System in a 3D Printed House

I was engaged in a project to design a compact VRF system alongside fresh/exhaust air for a unique 3D printed house. The HVAC drawings are required to be presented in 3D model.

HVAC Drawings | AutoCAD 2D

Whole-House Mini Split Design

A contractor engaged me to help design a mini split system for his new house project. We had discussed the pre-requisition requirements. I designed and produced the final layout drawings for him.

SAMPLE WORK

Professional Service

Companies who are involved in niche markets and innovative solutions can engage me as their in-house consultant or technical advisor for HVAC related matters.