{"id":14818,"date":"2023-05-09T16:09:21","date_gmt":"2023-05-09T08:09:21","guid":{"rendered":"https:\/\/aircondlounge.com\/?p=14818"},"modified":"2024-03-26T12:04:34","modified_gmt":"2024-03-26T04:04:34","slug":"how-ceiling-cassette-mini-splits-work","status":"publish","type":"post","link":"https:\/\/aircondlounge.com\/how-ceiling-cassette-mini-splits-work\/","title":{"rendered":"How Ceiling Cassette Mini Splits Work"},"content":{"rendered":"\n
Ceiling cassette mini splits are one of the different types of mini splits. They work differently from other types of mini splits. Some people are considering a ceiling cassette mini split but they want to know how it works. So, I’ll explain.<\/p>\n\n\n\n
Ceiling cassette mini splits work by supplying air in multiple directions for uniform air distribution. The air is then returned via the center return grille where a washable filter can be found. A fresh air duct can be connected to the ceiling cassette mini splits to introduce clean fresh air into the space.<\/strong><\/p>\n\n\n\n Ceiling cassette mini splits offer much more functionalities than wall-mounted mini splits. Understanding how ceiling cassette mini splits work can help you make an informed decision.<\/p>\n\n\n\n A mini split consists of two separate units known as the indoor unit and the outdoor unit.<\/p>\n\n\n\n The indoor unit is also known as the evaporator or the air handler while the outdoor unit is also known as the condenser or the compressor.<\/p>\n\n\n\n Most mini splits today can heat and cool, regardless of their types.<\/p>\n\n\n\n In cooling mode, the indoor unit is responsible for heat absorption and the outdoor unit is responsible for heat rejection. In heating mode, their responsibility reversed.<\/p>\n\n\n\n The mini split system transfers heat between the indoor unit and the outdoor unit via the refrigerant line.<\/p>\n\n\n\n You can choose from a few types of indoor units based on your preferences and applications. The 5 types of mini split indoor units are wall mounted, ceiling cassette, ceiling ducted, floor standing and floor mounted.<\/p>\n\n\n\n Each type of mini split indoor unit has its own unique features and applications. To find out more, kindly read my other blog post titled: 5 Types of Mini Split Indoor Units (How to Choose)<\/a>.<\/p>\n\n\n\n In this blog post, we’ll dive deeper into the ceiling cassette type of mini split indoor unit.<\/p>\n\n\n\n A ceiling cassette unit mainly consists of a front panel, a cooling\/heating coil and a blower fan.<\/p>\n\n\n\n The front panel of a ceiling cassette unit typically has 4 supply air vents shown as A, B, C & D in the below photo:<\/p>\n\n\nHow Mini Splits Work<\/h2>\n\n\n\n
How Ceiling Cassettes Work<\/h2>\n\n\n\n