{"id":14800,"date":"2023-05-09T12:26:18","date_gmt":"2023-05-09T04:26:18","guid":{"rendered":"https:\/\/aircondlounge.com\/?p=14800"},"modified":"2024-03-26T12:04:44","modified_gmt":"2024-03-26T04:04:44","slug":"can-mini-split-condenser-be-installed-in-attic","status":"publish","type":"post","link":"https:\/\/aircondlounge.com\/can-mini-split-condenser-be-installed-in-attic\/","title":{"rendered":"Can Mini Split Condenser Be Installed in Attic?"},"content":{"rendered":"\n
Mini split condenser is an important piece of equipment. It is the heart of the mini split system. Some people want it to be installed in the attic but they wonder if it’ll work. So, I’ll explain how the system works and what can be done.<\/p>\n\n\n\n
Under most circumstances, it is not recommended to install a mini split condenser in the attic.<\/strong> However, it is possible to install a mini split condenser in the attic given that the attic space temperature is within the operating temperature recommended by the mini split manufacturer.<\/strong><\/p>\n\n\n\n The attic is not the best place for mini split condenser. However, there are things that you can do to make this work without sacrificing much of the performance and lifespan of the mini split system.<\/p>\n\n\n\n There is a reason why mini split condenser is not recommended to be installed in the attic. Understanding how a mini split works can give you more insights.<\/p>\n\n\n\n A mini split system consists of two separate units known as the condenser and the evaporator.<\/p>\n\n\n\n The condenser is also known as the outdoor unit and the evaporator is also known as the indoor unit.<\/p>\n\n\n\n Nowadays, mini splits can heat and cool.<\/p>\n\n\n\n In cooling mode, the evaporator absorbs heat and the condenser rejects heat to the surrounding air. In heating mode, the condenser absorbs heat from the surrounding air. The heat is then transferred to the evaporator to provide warm air.<\/p>\n\n\n\n The mini split system transfers heat between the evaporator and the condenser via the refrigerant line.<\/p>\n\n\n\n Whether it is cooling or heating, the mini split condenser needs the outside air to function. Without it, the condenser will suffer performance degradation or stop working.<\/p>\n\n\n\n Every mini split has an operating temperature range. This is a requirement provided by mini split manufacturers, and different mini splits have different requirements.<\/p>\n\n\n\n Take this Senville LETO mini split<\/a> as an example. From the attached specification sheet, the outdoor unit operating temperature in cooling mode is between 5\u00b0F and 122\u00b0F.<\/p>\n\n\n\n So, if your attic space temperature is too high (exceeds 122\u00b0F), the mini split will not work.<\/p>\n\n\n\n During summer, the outdoor temperature can easily reach 100\u00b0F in some places. Given that hot air naturally rises and the attic is right under the roof, the attic space temperature could easily stop a mini split from working due to overheating.<\/p>\n\n\n\n Therefore, you must ensure that the attic space temperature does not exceed the maximum operating temperature of the mini split condenser in order for it to function properly<\/strong>.<\/p>\n\n\n\n See which of the best mini splits<\/a> have the widest operating range.<\/p>\n\n\n\n A few options to reduce the attic space temperature will be discussed in the following. Some of them require additional cost if you’re keen to install the mini split condenser in the attic.<\/p>\n\n\n\n In order to install a mini split condenser in the attic and have it work properly, the mini split condenser should be positioned such that warm air is blowing directly out of the attic<\/strong>, through an attic gable grille.<\/p>\n\n\n\n To ensure the warm air exits the attic efficiently, a short piece of duct may be attached to the discharge side of the mini split condenser.<\/strong> However, this may be considered an illegal modification which may lead to a warranty void.<\/p>\n\n\n\n With the discharge air being handled, next is the control of the attic space temperature to ensure the operating temperature requirement of the mini split condenser is met.<\/p>\n\n\n\n A power ventilation system is needed<\/strong> to introduce outside air into the attic to keep the attic space temperature below the maximum operating temperature of the mini split condenser.<\/p>\n\n\n\n As mentioned earlier, mini split condenser needs the outside air to function. With a ventilation system in place, the attic space temperature is approximately the same as the outdoor temperature.<\/p>\n\n\n\n The power ventilation system should consist of a ventilation fan controlled by a thermostat. The thermostat is set to operate the fan whenever the attic space temperature rises above the setpoint. This affordable Attic Ventilator<\/a> is a good example.<\/p>\n\n\n\n With that, the attic space temperature can be controlled for the mini split condenser.<\/p>\n\n\n\n In addition, the attic should also be well insulated<\/strong> to shield away the heat during summer and keep the heat inside during winter. Without insulation, the attic space temperature will fluctuate greatly, resulting in the need of a more powerful ventilation system.<\/p>\n\n\n\n Once the attic space temperature is controlled, a mini split condenser can be installed in the attic and no performance issue should be seen.<\/p>\n\n\n\n In heating mode, the mini split condenser produces condensate water. Normally, this condensate water will drip on the ground. But, if the mini split condenser is placed in the attic, the condensate water must be channeled outside via a drain pipe.<\/p>\n\n\n\n To prevent the condensate water from freezing, a Heat Trace<\/a> may be required along the drain pipe. In addition, a Drain Pan<\/a> may be required under the mini split condenser to catch the condensate water.<\/p>\n\n\n\n By the way, if you want to learn more about mini split especially how to design it for your house, consider my Mini Split (eBook)<\/a>. You’ll learn what is Mini Split, how to choose and more importantly, spark more design ideas to improve the energy efficient of your house. But, if you need a second opinion or want someone to help you design, then you can consider my consultation service.<\/p>\n\n\n Consultation Service<\/p><\/div>\n Ask me for HVAC advice such as brand selection, best model, benefits, features, placement, duct size, grille size, how to design, design check, verification and other HVAC related queries.<\/p><\/div>\n How Mini Split Works?<\/h2>\n\n\n\n
Mini Split Operating Temperature<\/h3>\n\n\n\n
Installing a Mini Split Condenser in Attic<\/h2>\n\n\n\n
Controlling Attic Space Temperature<\/h3>\n\n\n\n
Handling Mini Split Condensate Water<\/h3>\n\n\n\n